Display opening
Check the 70.00 × 57.00 mm minimum viewing area and the different front and rear glass widths against the enclosure opening.
Navigate

Rotate, zoom and inspect the product. Loads on request.
Front rendering of S04819D, showing the display artwork and glass outline. Materials and fine geometry are visual references for the OEM project.
OEM DISPLAY REFERENCE
S04819D is an HTN, positive-mode segmented LCD reference with separate Set Heat to and Set Cool to fields, a larger lower numeric field, and operating-mode icons. The glass has a pin row along each side.
Images, 3D geometry and listed parameters are OEM reference information. Final dimensions, electrical requirements, optical configuration and construction are confirmed for your project.
Short product video. Playback starts when you press play.
01 / REFERENCE CONFIGURATION
A reference configuration for discussing your LCD project. Final specifications are subject to project confirmation.
| Model reference | S04819D |
|---|---|
| Display mode | HTN, positive |
| Rear glass width × height | 78.00 ± 0.20 × 60.00 ± 0.20 mm |
| Front glass width × height | 73.00 ± 0.20 × 60.00 ± 0.20 mm |
| Minimum viewing area | 70.00 × 57.00 mm |
| LCD thickness | 2.80 mm maximum |
| Glass thickness per layer | 1.10 ± 0.10 mm |
| Pin pitch | 2.54 mm |
| Connection | Pins along both side edges |
| LCD operating voltage | 3.0 V |
| Drive condition | 1/4 duty, 1/3 bias |
| Frame frequency | 64 Hz |
| Viewing direction | 12 o’clock |
| Rear polarizer | Transflective, adhesive |
| Front polarizer | Transmissive, adhesive |
| Operating temperature | 0 °C to +50 °C |
| Storage temperature | −10 °C to +60 °C |
02 / OEM DESIGN
Bring your requirements. We will review the configuration with you.
Check the 70.00 × 57.00 mm minimum viewing area and the different front and rear glass widths against the enclosure opening.
Review the two side pin rows at 2.54 mm pitch together with the PCB layout. Confirm lead clearance and pin assignments for the assembly.
A transflective rear polarizer and a 12 o’clock viewing direction are listed. Evaluate the complete display under the lighting and viewing position of the controller.
03 / APPLICATION DIRECTION
Use this reference to plan a temperature-controller panel with separate heating and cooling setpoints. Confirm the numeric fields, units and required mode indications for the controller.
04 / PRODUCT SUPPORT
The reference lists 3.0 V LCD operating voltage, 1/4 duty, 1/3 bias and 64 Hz frame frequency. Check these requirements against your LCD driver; final electrical requirements are confirmed for the project.
Review the required heating and cooling setpoint digits, units and status icons together with the larger lower numeric field. Artwork and segment mapping are confirmed for the project.
YOUR NEXT LCD PROJECT
Share your required display content, enclosure space, drive arrangement, operating environment and target quantity.