EV Charger With Screen: How to Choose the Display, Touch and Cover Glass

For an EV charger with screen, settle the environment before the panel: sun on the glass, rain and gloves on the touch surface, impacts on the front, and what the screen is legally required to show. That usually points to a high-brightness TFT behind an AR-coated, optically bonded cover, projected capacitive touch tuned for water, cover glass that passes the enclosure’s IK test, and a front seal that holds its IP rating. Simple wallboxes can get by with a backlit segment LCD. The large advertising screens on some charging stations are a separate product from the user-interface display covered here.

Request a quote Touch panel and cover lens options

Front display stack of an EV charger with screenCross-section of an outdoor charger display, front to back: anti-reflection coating, cover glass that forms part of the enclosure for the IK impact test, optical bonding layer that fills the air gap, projected capacitive touch sensor, LCD cell and backlight. A gasket between the cover glass and the enclosure provides the IP seal. Notes: AR coating lowers front reflectance from about 4.4 percent to 1.5 percent; IK10 equals 20 joules, a 5 kilogram mass dropped 0.40 meters; IP65 means dust-tight and protected against 6.3 millimetre water jets.Front of an EV charger with screen: what each layer answers forCross-section, not to scale. Light and impacts arrive from the left.EnclosureGasket = IP sealAR coating: reflectance about 4.4 % to 1.5 %Cover glass: part of the IK testOptical bonding: no air gapPCAP touch: tuned for rain, glovesLCD: high-brightness TFTBacklight: dimmed by a light sensorSunImpactIK10 = 20 J: a 5 kg mass dropped 0.40 m (IEC 62262)IP65 = dust-tight + 6.3 mm water jets (IEC 60529)
Figure: the cover glass, bonding, touch sensor and gasket decide how an EV charger screen copes with sun, rain and impacts.

Which display fits which charger

Start from what the user has to do at the charger. A wallbox that only shows status needs far less than a public post that takes payment and must show a price.

Charger and screen jobDisplay that fitsCatalogue examples
Wallbox: charging status, current, fault codesBacklit segment LCD; a negative VA panel with a white or colored backlight is the usual lookPower supply and charger LCDs, such as S3321D (VA, 90.0 × 30.5 mm viewing area, −20 to +70 °C) and S4464D (VA, −30 to +80 °C)
Public AC post: authentication, price, session data5 to 7 inch TFT with PCAP touchS700MIWE-28C0 (7-inch touch assembly), S700GG-42 (7-inch PCAP panel, GT911, I²C)
DC fast charger: payment, connector choice, help screens7 to 10.1 inch high-brightness TFT, bonded cover, PCAPS10MB1XH-07C0 (10.1 in, 1024 × 600, LVDS, PCAP), S10GF2-94 (10-inch PCAP, FT5426G, I²C)
EV charging station with advertising screenA large-format signage display, usually a separate unitOutside our range: our TFT modules run from 1.3 to 15.6 inches

Don’t rule out the segment LCD. If the owner controls the wallbox from a phone app, a TFT adds a display controller, software and power for information the app already shows.

Brightness: outdoor sun on the glass

Direct sunlight runs from 32,000 to 100,000 lx. The light that reflects off the front of the screen sits on top of the image as a gray veil, and its luminance is the illuminance divided by π, times the screen’s reflectance (Chen, Tan and Wu, Optics Express, 2017). At 50,000 lx a front reflectance of 4.4 %, measured on a phone LCD in that paper, adds 50,000 ÷ π × 0.044 ≈ 700 cd/m² of veil. A single-layer AR coating at 1.5 % brings it down to about 240 cd/m².

That is why the cover treatment matters as much as the backlight. An air gap between cover glass and LCD adds two more reflecting surfaces; optical bonding fills the gap with clear adhesive and removes them (see optical bonding vs air gap). Then size the backlight for the contrast you need, and let an ambient light sensor turn it down when the sun is gone. An LED backlight left at full power all night only adds heat inside a sealed box. Our sunlight readable TFT guide compares the options.

EV charger with touch screen: rain, gloves and reach

Projected capacitive (PCAP) touch senses the change in capacitance a finger causes through the cover glass. Rain also changes it, so the touch controller has to tell a film of water from a finger, and a gloved finger gives a weaker signal through thick glass. Ask which water-handling and glove modes the controller supports, and test them on your actual cover thickness. The controllers on our 7-inch and 10-inch PCAP references are the GT911 and FT5426G, both reporting over I²C; the trade-offs of thick glass, gloves and water are covered in capacitive touch with gloves, water and thick glass.

Placement matters as much as tuning. The US Access Board’s guidance for accessible chargers puts operable parts no higher than 48 inches above the ground, and recommends keeping them above the 15-inch minimum. A screen that needs touch must sit inside that range. A screen that only displays can go higher.

IK10 rating: what the cover glass has to survive

IEC 62262 rates how well an enclosure resists mechanical impact, and IEC 61851-1, the general EV charging standard, lists it among its normative references. On a charger with a screen, the cover glass is part of the enclosure front, so an IK10 impact rating, or whatever code the charger claims, has to hold with the glass in place.

IK codeImpact energyTest mass and drop height
IK085 J1.7 kg from 0.30 m
IK0910 J5 kg from 0.20 m
IK1020 J5 kg from 0.40 m

Worked example: how much harder is IK10 than IK08? Potential energy is m × g × h. For IK08: 1.7 kg × 9.81 m/s² × 0.30 m = 5.0 J. For IK10: 5 kg × 9.81 m/s² × 0.40 m = 19.6 J, rounded to 20 J. So IK10 asks the front to absorb four times the energy, delivered by a mass three times heavier. Glass thickness, the strengthening process and how the glass is supported at its edges all change the outcome, which is why the test is run on the assembled front, not on a loose sheet of glass.

Write the IK code the charger must meet into the cover glass RFQ, along with the mounting method. A cover glass qualified in one bezel can fail in another that supports it differently.

IP65 at the front: sealing the display window

IEC 60529 defines the IP code. A first digit of 6 means dust-tight. A second digit of 5 means water jets from a 6.3 mm nozzle at 12.5 liters per minute; 6 means powerful jets from a 12.5 mm nozzle at 100 liters per minute. A standard LCD module is not sealed to these levels. The seal is the gasket or adhesive between the cover glass and the enclosure, and the module sits behind it.

Condensation is the other outdoor problem. Warm, damp air trapped in the gap between cover glass and LCD can fog when the glass cools at night. Bonding removes that gap; if you keep an air gap, plan venting or a dry seal and test through temperature cycles.

What the screen has to show

In the US, chargers built with federal highway funds fall under 23 CFR 680. Section 680.116 requires the price to be displayed before a charging session starts, based on the price per kWh, shown as the real-time price, and held for the session, with any other fees clearly displayed and explained. That is a screen requirement, not just a billing one.

Federal agency chargers also follow Section 508, which the Access Board summarizes for chargers: the screen visible from a point 40 inches above the ground, a speech-output option, no flashing faster than 3 times a second, and a text mode with characters at least 3/16 inch (about 4.8 mm) tall. Check these against your layout before fixing the screen size.

EV charger display FAQs

What is IK10 rating?

IK10 is the IEC 62262 impact code for 20 joules, applied in the test by a 5 kg mass dropped from 0.40 m. On an EV charger it applies to the whole enclosure front, including the display cover glass.

Does an EV charger with touch screen work in rain and with gloves?

It can, if the PCAP controller is tuned for it. Water and gloves both change the capacitance the controller reads, so check its water and glove modes and test them on the final cover glass thickness.

Is IP65 enough for an outdoor EV charger display?

IP65 means dust-tight and protected against 6.3 mm water jets, and the charger’s own rating decides what the front must meet. The display window is sealed by the cover glass and gasket, so that seal, not the LCD module, decides whether the front meets the rating.

What does a public EV charger screen have to show in the US?

Chargers funded under 23 CFR 680 must show the real-time price per kWh before the session starts, with other fees explained. Chargers owned by federal agencies also follow Section 508 rules on screen visibility, speech output and text size.

Designing an EV charger with a screen? Send the screen size you have in mind, the enclosure’s IK and IP ratings, the host interface and the hours the screen faces the sun. We will suggest a display and touch stack from the catalogue or a custom build. See high-brightness TFT modules and touch panels and cover glass, or ask about an EV charger display.

Scroll to Top