Thermometer LCD Displays

Clinical, food and probe thermometers need a clear temperature reading in °C or °F with hold, max/min and battery icons. Food and probe thermometers often add a timer, a target temperature or a second probe field.

Small TN, HTN and VA glass at around 3 V keeps battery life long. VA negative glass with a backlight is popular on food thermometers that are used outdoors and at night.

Thermometer LCD references

The table lists 13 thermometer LCD references with full drawing data: 5 VA, 4 HTN, 3 TN and 1 FSTN. LCD operating voltages run from 3.0 V to 3.3 V, and the most common drive is 1/4 duty, 1/3 bias. The widest operating range on these drawings is −20°C to +70°C.

ModelLCD typeViewing areaVoltageDriveOperating temp.Connection
S3982DHTN, positive42.5 × 16.5 mm3.0 V1/4 duty, 1/3 bias−10°C to +60°CZebra (elastomer) connector
S4089DVA, negative20.0 × 20.0 mm3.3 V1/4 duty, 1/3 bias−10°C to +60°CZebra (elastomer) connector
S4136DHTN, positive49.8 × 21.2 mm3.0 V1/4 duty, 1/3 bias−10°C to +60°CZebra (elastomer) connector
S4153DTN, positive40.0 × 18.0 mm3.0 V1/4 duty, 1/3 bias0°C to +50°CMetal pins
S4154DHTN, positive43.5 × 17.5 mm3.0 V1/4 duty, 1/3 bias−10°C to +60°C—
S4157DHTN, positive34.5 × 11.6 mm3.0 V1/4 duty, 1/3 bias−10°C to +60°CZebra (elastomer) connector
S4278DVA, negative45.2 × 18.09 mm3.3 V1/4 duty, 1/3 bias−10°C to +60°CFPC
S4334DVA, negative130.8 × 21.1 mm3.3 V1/4 duty, 1/3 bias−10°C to +60°CFPC
S4382DTN, positive28.68 × 20.68 mm3.0 V1/3 duty, 1/2 bias−20°C to +70°C—
S4391DFSTN, positive92.0 × 8.0 mm3.3 V1/4 duty, 1/3 bias−10°C to +60°CMetal pins
S4482DVA, negative50.9 × 25.8 mm3.3 V1/6 duty, 1/3 bias−10°C to +60°C—
S4483DVA, negative68.0 × 31.7 mm3.3 V—−10°C to +60°C—
S4697DTN, positive30.0 × 15.0 mm3.3 V1/4 duty, 1/3 bias0°C to +50°CMetal pins

More thermometer references

  • S3983D — Compact HTN thermometer display with flat glass contacts
  • S4044D — Chamfered HTN thermometer display with zebra contacts
  • S4404D — DFSTN food thermometer display reference
  • S4463D — DFSTN LCD
  • S4870D — TN LCD

Real samples on video

Short clips of real SuccessLCD samples for this application. Each player loads when you press play.

S3983D LCD sample in operation
S3983D · Food thermometer
S4870D LCD sample in operation
S4870D · Thermometer
S3984D LCD sample in operation
S3984D · Dual-probe thermometer

What to send for a custom thermometer LCD

  • Your display artwork, or a sketch of the digits, icons and legends you need
  • Outline, viewing area and thickness limits from your housing
  • LCD operating voltage, or the LCD driver or MCU you plan to use
  • Operating and storage temperature
  • Connection: metal pins, zebra, FPC or heat seal
  • Backlight colour, if any, and the expected annual quantity

Any reference above can be used as a starting point: tell us the model number and what needs to change.

Send your thermometer LCD requirements

Scroll to Top
Get a QuoteWhatsApp