PRODUCT EXPLORERFront view
S4480D front LCD product rendering on a white background

Six rendered views of S4480D. Select a thumbnail to switch views.

Front visualization of S4480D, an LCD reference design for portable power stations. The generated image illustrates product appearance; final construction is defined for the OEM project.

OEM DISPLAY REFERENCE · VA

S4480D
VA LCD

S4480D is a VA negative-mode segment LCD for portable power stations, with a 71.0 × 32.0 mm viewing area. The reference drawing specifies 4.5 V drive, a −20°C to +70°C operating range and a 12 o’clock viewing direction. Use it as the starting point for your OEM layout, connector and enclosure discussion.

VA LCDDisplay family
4.5 VLCD operating voltage
71.0 × 32.0 mmViewing area
Portable power stationsApplication direction

Tell us your display layout, quantity and target application.

A starting point for your custom display.

Images and parameters are reference information taken from the product drawing. Final dimensions, electrical requirements and construction are confirmed for your project.

Product video

The real S4480D sample in operation. The YouTube player loads when you press play.

S4480D LCD sample in operation

Watch on YouTube · SuccessLCD channel

01 / REFERENCE CONFIGURATION

S4480D key specifications.

A reference configuration for discussing your LCD project. Final specifications are subject to project confirmation.

Request datasheet and drawing

Need different digits, icons or outline? See custom segment LCD design.

S4480D reference specifications
Model referenceS4480D
Display modeVA, negative
Polarizers (front / rear)Transmissive / transmissive (needs backlight)
Viewing direction12 o’clock
Operating temperature−20°C to +70°C
Storage temperature−30°C to +80°C
LCD operating voltage4.5 V
Drive condition1/8 duty, 1/3 bias
Frame frequency80–128 Hz
ConnectorMetal pins
Pin / contact pitch2.54 mm pitch
Viewing area71.0 × 32.0 mm minimum
Glass outline78.0 × 39.0 mm

02 / OEM DESIGN

Customize the S4480D for your product.

Bring your requirements. We will review the configuration with you.

01

Display layout

Share the digits, symbols, icons or graphics needed for your portable power station interface.

02

Mechanical fit

Define the viewing window, available space, mounting method and connection position.

03

Electrical requirements

Confirm your host controller, supply, drive method and backlight requirements before sampling.

03 / APPLICATION DIRECTION

Portable power stations.

S4480D is presented as a reference for portable power stations. Review the drawing-based specification and the six product views, then tell us what your portable power station needs to show.

01

Information at a glance

Identify the readings, status indicators and control feedback your users need to see.

02

Designed around the enclosure

Coordinate the display opening, viewing direction and connection with the complete product.

03

Confirmed for your project

Agree the display configuration and sample requirements with our team.

ENGINEERING NOTES

What the S4480D specification means for your design.

How S4480D relates to LCD mode, drive, connection and integration choices, with links to the SuccessLCD engineering guides.

02

Drive: 1/8 duty, 1/3 bias

8 common electrodes share the segment lines. Set the controller to the duty, bias, voltage and frame frequency on the drawing. Duty and bias explained →

03

Negative display

A negative LCD needs a backlight; the look is close to a VFD or LED readout. VFD vs LCD →

Similar VA references

  • S3730DVA LCD for portable power stations, 108.0 × 60.0 mm viewing area
  • S4482DVA LCD for food thermometers, 50.9 × 25.8 mm viewing area
  • S4483DVA LCD for food thermometers, 68.0 × 31.7 mm viewing area
  • S4473DVA LCD for thermostats, 38.39 × 29.5 mm viewing area
  • S4488DVA LCD for towel dryers, 31.0 × 39.0 mm viewing area
  • S4489DVA LCD for clocks, 47.71 × 18.56 mm viewing area

Browse all VA LCD references →

All power supply and charger LCD references →

04 / PRODUCT SUPPORT

From the S4480D reference to your design.

Is S4480D a fixed specification?

This page presents a reference design for OEM discussions. The final specification and available customization are confirmed against your project requirements.

What should I send for an OEM quotation?

Include S4480D, your application, display artwork, enclosure dimensions, electrical requirements, sample and production quantities, and target schedule.

Which drive and temperature settings does S4480D use?

The reference drawing for S4480D specifies a 1/8 duty, 1/3 bias drive condition, 4.5 V LCD operating voltage, an operating temperature of −20°C to +70°C and a storage temperature of −30°C to +80°C. The rear polarizer is transmissive, so the display is designed to be used with a backlight. These values can be adjusted for your project.

YOUR NEXT LCD PROJECT

Let’s shape your display.

Start with S4480D and tell us what your product needs.

Discuss S4480D ↗
Scroll to Top
Get a QuoteWhatsApp